Ask Copilot
Section · km 0.0–2.4

IB-01 Ashby Junction – Quarry Siding

2 open observations. Last inspected 12 Sep 2026, next due 11 Nov 2026.

Condition score

Attention
78 /100 · 82 on 26 Aug
Rail
80
Sleepers
79
Fasteners
79
Ballast
70
OBS-1030 ballast contamination · confirmed · −12.0
Vegetation
82
OBS-1031 vegetation encroachment · confirmed · −6.0

Internal Ralliyo metric, not a regulatory rating. Open observations deduct points by priority (high 12, medium 6, low 3), scaled by severity; pending observations count at half weight.

Condition trend

707580851 Jul29 Jul26 Aug23 Sep21 Oct25 Oct
AssetCategoryKmConditionOpen
SL-IB01-021Sleeper0.686—
FS-IB01-012-RFastener1.086—
FS-IB01-013-LFastener1.286—
VG-IB01-02Vegetation zone1.9861
SL-IB01-024Sleeper1.287—
SL-IB01-022Sleeper0.888—
BZ-IB01-01Ballast zone0.6881
SL-IB01-027Sleeper1.989—
FS-IB01-014-RFastener1.489—
FS-IB01-015-RFastener1.790—
SL-IB01-020Sleeper0.491—
FS-IB01-010-LFastener0.591—
VG-IB01-01Vegetation zone0.791—
SL-IB01-023Sleeper1.092—
SL-IB01-025Sleeper1.492—
FS-IB01-011-RFastener0.792—
FS-IB01-012-LFastener1.092—
FS-IB01-014-LFastener1.492—
FS-IB01-015-LFastener1.792—
RL-IB01-002Rail0.093—
SL-IB01-026Sleeper1.795—
BZ-IB01-02Ballast zone1.795—
RL-IB01-001Rail0.096—
FS-IB01-010-RFastener0.596—
FS-IB01-011-LFastener0.796—
FS-IB01-013-RFastener1.296—

Inspection history

InspectionSectionDateMethodImagesObservationsInspector
INS-2026-035IB-0112 Sep 2026Hi-rail vehicle · forward camera42M. Haddad

Maintenance

MNT-305 Ballast cleaning and top-up, IB-01new